A user-friendly patient monitor with a touch screen that now includes Masimo SET Pulse Oximetry!

Key Features:

  • ST segment monitoring and 72 hours trend data analysis
  • Built-in battery
  • New for 2015! Masimo SET® Pulse Oximetry — ask your Avante representative for details
  • NIBP list and OxyCRG dynamic view display
  • Drug dose calculations
  • Large font display with 4, 6 and 8 waveforms shown
  • Built-in thermal recorder
  • Networkable with a central monitoring system via a wireless or wired network
  • Compact design convenient for mobile monitoring
  • Multi-lingual settings
  • Includes veterinary accessories for parameters ordered

Each monitor will automatically include the CO2 and IBP ports. These parameters are listed as options and are NOT standard. Your veterinary or research facility has the ability to upgrade to any of these parameters at a later time without having to send the monitor back! Call a us for further details.

Documents and Resources:

**To download click below**

NIBP Connector Guide

SPO2 Probe Identifier

    Year Manufacturer's Warranty

    Avante Medical Surgical warranties its equipment to be free of defects in materials and workmanship under normal use and with appropriate maintenance. Length of warranty varies from product to product, so please confirm with your Avante Medical Surgical representative for specific warranty coverage. For plastics, rubber, or other expendable items, we warrant only that such parts will be free of defects in materials and workmanship at the time of purchase.

    PHYSICAL DIMENSIONS:

    • 21.9” H x 13.2” W x 9.23” D (555 mm H x 335 mm W x 235 mm D)
    • Weight - 11bs (5kg)

    APPLICATION:

    • Veterinary patients

    POWER:

    • Power Source - External AC power or internal battery
    • AC Power - 100-240VAC, 50/60Hz, <150VA
    • Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour)
    • Operating time after the first alarm of low battery (10 min.)

    ENVIRONMENTAL:

    • Working Temperature: 5-40 C
    • Storage Temperature: 0-65 C
    • Working Humidity: 30-75%
    • Storage Temeprature: ≤80%
    • Operating Altitude: Up to 5,000 meters
    • Hyperbaric Pressure - Up to 405.3 kPa

    PERFORMANCE SPECIFICATIONS:

    • Display - 12.1” color TFT, Touch Screen
    • Resolution - 800 x 600 pixels
    • Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
    • Indicator - Alarm indicator; Power indicator QRS beep and alarm sound
    • Trend Time - 72 hours
    • Recorder - Built-in, thermal array, 2 channels
    • Record - Width 48mm
    • Recorder - Paper 50mm
    • Record - Speed 25mm/s, 50mm/s
    • OxyCRG - Combines HR, SpO2, and resp. trends into a single graph ECG
    • Input - 5-lead ECG cable and standard AAMI line for connection
    • Lead Choice - I, II, III, aVR, aVF, aVL, V
    • Gain Choice - x0.125, x0.25, x0.5, x1.0, x2.0

    FILTER:

    • Diagnostic mode - 0.05 – 100Hz
    • Monitoring mode - 0.05 – 75Hz
    • Surgical mode - 1 – 20Hz
    • Frequency Characteristic - 0.05-40 Hz
    • ECG Waveforms - 7 channels
    • Penetration Voltage - 4000VAC 50/60Hz
    • Sweep Speed - 12.5, 25 and 50 mm/s
    • HR Display Range - 30-300bpm
    • Accuracy - 1% or 1bpm, whichever is greater
    • S-7 Segment Detection - 7 channels
    • Measurement Range - -2.0mv – +2.0mv
    • Arrhythmia Analysis - 13 types
    • Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm

    RESP:

    • Measure Method - RA-LL impedance
    • Range - 0-120 rpm
    • Accuracy - + 3 rpm
    • Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm
    • Sweep Speed - 12.5 and 25 mm/s

    NIBP:

    • Measuring Technology - Automatic oscillating measurement
    • Cuff Inflating - <30s (0 – 300mmHg, standard adult cuff
    • Measuring Period - AVE<40s
    • Mode - Manual, Auto, STAT
    • Measuring Interval in AUTO Mode - 2 min-4 hrs
    • Pulse Rate Range - 30-250 (bpm)
    • Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
    • Resolution - 1mmHg
    • Accuracy - Pressure, Maximum Mean error 5mmHg, Max. Standard deviation 8mmHg
    • Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
    • Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg

    TEMP:

    • Range - 0 – 50 C (32 – 122 F)
    • Accuracy - Without sensor
    • Display Resolution - 0.1 C
    • Alarm Upper-lower Limit Setting - Upper limit 0-50 C, Lower limit 0-50 C
    • Channel - 2 channels, provide T1, T2, ΔT
    • Alarm Limit Setting - 10-50 C

    MASIMO SET SPO2:

    • Measuring Range:
      • SpO2: 1~100 %
      • PR: 25~20 %
    • SpO2 Accuracy (non-motion):
      • Adult Pediatric: 70~69%: unspecified
      • Neonate: 70~69 %: unspecified
    • SpO2 Accuracy (motion):
      • Adult Pediatric: 70~69% : unspecified
      • Neonate: 70~69 % : unspecified
    • PR Accuracy (non-motion):
      • Adult Pediatric Neonate: 25?240 bpm: ±3 bpm
    • PR Accuracy (motion):
      • Adult Pediatric Neonate: 25<span 20.8px;"="">~240 bpm: ±5 bpm
    • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
      • SpO2: ±2 %
      • PR: ±3 bpm
    • Modes:
      • Averaging mode: 2,4,8,10,12,14 and 16 s
      • Sensitivity: Normal, APOD and Maximum

    IBP (OPTION):

    • Measurement Range - -10-300mmHg
    • Channel - 2 channels
    • Pressure Transducer Sensitivity, 5μV/V/mmHg
    • Impedance Range - 300-3000Ω
    • Transducer Sites - ART, PA, CVP, RAP, LAP, ICP
    • Resolution - 1mmHg
    • Accuracy - 1mmHg or 2%, whichever is greater
    • Alarm range - -10-300mmHg

    ETCO2 (OPTION) (RESPIRONICS):

    • Mode of Sampling - Sidestream
    • Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
    • CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
    • CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated)
    • CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg)
    • CO2 Accuracy - 0-40 mmHg 2 mmHg; 41-70 mmHg 5% of reading; 71-100 mmHg 8% of reading; 101-150 mmHg 10% of reading; Above 80 breath per minute 12% of reading
    • Sampling Rate - 100Hz
    • Respiration Rate - 2-150 bpm
    • Respiration Rate Accuracy - 1 breath
    • Response Time - <3 seconds - includes transport time and rise time
    • Inspired CO2 Measurement Range - 3-50 mmHg

    Avante Ships from Kentucky via UPS Ground

    As soon as your order ships, we will send you a shipping notice with a tracking number. Use the map below to estimate the transit time needed for your item to be delivered from our warehouse to you:


      Fast Shipping

      We do our best to ship FAST and make it easy for you.  At the top of this page, we have noted how long it normally takes to process and ship your order with estimated delivery times.  We will send you an email confirmation with the tracking number as soon as your order ships.

      Please see our Shipping Policy for full details.

      Easy Returns

      Things don't always work out, we get it.  We'll do our very best to make your return simple and easy.  Please email us and we'll provide all the return instructions for your specific item and an RMA number (required).

      Please see our Return Policy for full details.

      Customer Reviews

      Be the first to write a review
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)